Investigation of Some Regular X-ray Imaging Parameters in Suggestive Radiography of Four Hospitals in Bangladesh

Analytic radiography is a normal image testing technique which has been utilized for quite a long time. It is recommended by specialists so they can identify any problem in patients' bodies without a cut. Thinking about its wide use, the principle objective of this investigation is to give a...

Бүрэн тодорхойлолт

Номзүйн дэлгэрэнгүй
Үндсэн зохиолч: Meaze, AKM Moinul Haque
Формат: Өгүүллэг
Хэл сонгох:англи
Хэвлэсэн: Suan Sunandha Science and Technology Journal 2025
Нөхцлүүд:
Онлайн хандалт:https://repository.auw.edu.bd/handle/123456789/904
_version_ 1857448883016171520
author Meaze, AKM Moinul Haque
author_facet Meaze, AKM Moinul Haque
author_sort Meaze, AKM Moinul Haque
collection institutional Repository
description Analytic radiography is a normal image testing technique which has been utilized for quite a long time. It is recommended by specialists so they can identify any problem in patients' bodies without a cut. Thinking about its wide use, the principle objective of this investigation is to give a top notch picture by keeping the radiation portion as low as conceivable through identifying any variety in quality control (QC) boundaries. In this work, some standard quality control boundaries, for example, voltage exactness, time precision test, tube yield linearity, half value layer (HVL) of x-beam were measured. These quality control (QC) boundaries were estimated by a dosimeter keeping a distance of 100 cm from source. The voltage precision went from 0.31% to 4.67% and the time exactness test went from 0% to 2.29%. The consequences of this investigation show that all the QC boundaries are inside the acceptable level which guarantees the advancement of the low portion conveyed to the patients.
format Article
id 123456789-904
institution Asian University for Women
language English
publishDate 2025
publisher Suan Sunandha Science and Technology Journal
record_format dspace
spelling 123456789-9042026-02-18T06:15:02Z Investigation of Some Regular X-ray Imaging Parameters in Suggestive Radiography of Four Hospitals in Bangladesh Meaze, AKM Moinul Haque Diagnostic radiography, Quality control (QC), X-ray, HVL, Dosimeter Analytic radiography is a normal image testing technique which has been utilized for quite a long time. It is recommended by specialists so they can identify any problem in patients' bodies without a cut. Thinking about its wide use, the principle objective of this investigation is to give a top notch picture by keeping the radiation portion as low as conceivable through identifying any variety in quality control (QC) boundaries. In this work, some standard quality control boundaries, for example, voltage exactness, time precision test, tube yield linearity, half value layer (HVL) of x-beam were measured. These quality control (QC) boundaries were estimated by a dosimeter keeping a distance of 100 cm from source. The voltage precision went from 0.31% to 4.67% and the time exactness test went from 0% to 2.29%. The consequences of this investigation show that all the QC boundaries are inside the acceptable level which guarantees the advancement of the low portion conveyed to the patients. 2025-07-31T07:53:30Z 2025-07-31T07:53:30Z 2023 Article https://repository.auw.edu.bd/handle/123456789/904 en application/pdf Suan Sunandha Science and Technology Journal
spellingShingle Diagnostic radiography, Quality control (QC), X-ray, HVL, Dosimeter
Meaze, AKM Moinul Haque
Investigation of Some Regular X-ray Imaging Parameters in Suggestive Radiography of Four Hospitals in Bangladesh
title Investigation of Some Regular X-ray Imaging Parameters in Suggestive Radiography of Four Hospitals in Bangladesh
title_full Investigation of Some Regular X-ray Imaging Parameters in Suggestive Radiography of Four Hospitals in Bangladesh
title_fullStr Investigation of Some Regular X-ray Imaging Parameters in Suggestive Radiography of Four Hospitals in Bangladesh
title_full_unstemmed Investigation of Some Regular X-ray Imaging Parameters in Suggestive Radiography of Four Hospitals in Bangladesh
title_short Investigation of Some Regular X-ray Imaging Parameters in Suggestive Radiography of Four Hospitals in Bangladesh
title_sort investigation of some regular x ray imaging parameters in suggestive radiography of four hospitals in bangladesh
topic Diagnostic radiography, Quality control (QC), X-ray, HVL, Dosimeter
url https://repository.auw.edu.bd/handle/123456789/904
work_keys_str_mv AT meazeakmmoinulhaque investigationofsomeregularxrayimagingparametersinsuggestiveradiographyoffourhospitalsinbangladesh