Measurements of photoneutron dose rate for 15 MV photon beam from medical linear accelerator using neutron survey meter

High-energy medical linear accelerators (>10MV) are increasingly used in the medical field to treat cancer patients depending on the treatment organ and patient physic. Medical linear accelerators (Linacs) operating above 10 MV photon beam produce unwanted neutrons (photoneutron) by means of ph...

Descripció completa

Dades bibliogràfiques
Autor principal: Meaze, AKM Moinul Haque
Format: Article
Idioma:anglès
Publicat: Luminescience 2025
Matèries:
Accés en línia:https://repository.auw.edu.bd/handle/123456789/908
_version_ 1857449008002236416
author Meaze, AKM Moinul Haque
author_facet Meaze, AKM Moinul Haque
author_sort Meaze, AKM Moinul Haque
collection institutional Repository
description High-energy medical linear accelerators (>10MV) are increasingly used in the medical field to treat cancer patients depending on the treatment organ and patient physic. Medical linear accelerators (Linacs) operating above 10 MV photon beam produce unwanted neutrons (photoneutron) by means of photonuclear reaction (γ, n) between bremsstrahlung photon beams and constituent materials of Linac head. This study involved the measurement of the neutron dose rate from photon beam of medical linear accelerator (Elekta Synergy) operated at 15 MV photon. For the measurement of dose rate, a neutron survey meter LB 6411 probe was used. Neutron dose rate was obtained as a function of delivered dose, field size and detector position. In the study neutron dose rate was found 13.14 mSv/h at a field size of 10 × 10 cm2 at position (0, 90, 0) cm for 350 cGy and 9.26 mSv/h at 5 × 5 cm2 field size at position (0, 80, 0) cm for 200 cGy photon dose delivery. The dose rate varied with respect to detector position in an irregular manner; 2.95 mSv/h at position (-100, 0, 0) cm -on the side of maze entrance and 4.85 mSv/h at position (100, 0, 0) cm -off side of maze entrance.
format Article
id 123456789-908
institution Asian University for Women
language English
publishDate 2025
publisher Luminescience
record_format dspace
spelling 123456789-9082026-02-18T06:15:22Z Measurements of photoneutron dose rate for 15 MV photon beam from medical linear accelerator using neutron survey meter Meaze, AKM Moinul Haque Cancer, Radiotherapy, Medical Linac, Bremsstrahlung, Survey meter, Photoneutron, Neutron Dose Rate High-energy medical linear accelerators (>10MV) are increasingly used in the medical field to treat cancer patients depending on the treatment organ and patient physic. Medical linear accelerators (Linacs) operating above 10 MV photon beam produce unwanted neutrons (photoneutron) by means of photonuclear reaction (γ, n) between bremsstrahlung photon beams and constituent materials of Linac head. This study involved the measurement of the neutron dose rate from photon beam of medical linear accelerator (Elekta Synergy) operated at 15 MV photon. For the measurement of dose rate, a neutron survey meter LB 6411 probe was used. Neutron dose rate was obtained as a function of delivered dose, field size and detector position. In the study neutron dose rate was found 13.14 mSv/h at a field size of 10 × 10 cm2 at position (0, 90, 0) cm for 350 cGy and 9.26 mSv/h at 5 × 5 cm2 field size at position (0, 80, 0) cm for 200 cGy photon dose delivery. The dose rate varied with respect to detector position in an irregular manner; 2.95 mSv/h at position (-100, 0, 0) cm -on the side of maze entrance and 4.85 mSv/h at position (100, 0, 0) cm -off side of maze entrance. 2025-08-04T09:54:15Z 2025-08-04T09:54:15Z 2023 Article https://repository.auw.edu.bd/handle/123456789/908 en application/pdf Luminescience
spellingShingle Cancer, Radiotherapy, Medical Linac, Bremsstrahlung, Survey meter, Photoneutron, Neutron Dose Rate
Meaze, AKM Moinul Haque
Measurements of photoneutron dose rate for 15 MV photon beam from medical linear accelerator using neutron survey meter
title Measurements of photoneutron dose rate for 15 MV photon beam from medical linear accelerator using neutron survey meter
title_full Measurements of photoneutron dose rate for 15 MV photon beam from medical linear accelerator using neutron survey meter
title_fullStr Measurements of photoneutron dose rate for 15 MV photon beam from medical linear accelerator using neutron survey meter
title_full_unstemmed Measurements of photoneutron dose rate for 15 MV photon beam from medical linear accelerator using neutron survey meter
title_short Measurements of photoneutron dose rate for 15 MV photon beam from medical linear accelerator using neutron survey meter
title_sort measurements of photoneutron dose rate for 15 mv photon beam from medical linear accelerator using neutron survey meter
topic Cancer, Radiotherapy, Medical Linac, Bremsstrahlung, Survey meter, Photoneutron, Neutron Dose Rate
url https://repository.auw.edu.bd/handle/123456789/908
work_keys_str_mv AT meazeakmmoinulhaque measurementsofphotoneutrondoseratefor15mvphotonbeamfrommedicallinearacceleratorusingneutronsurveymeter