STUDIES OF DOSIMETRY PROTOCOLS FOR ACCELERATED PHOTONS AND ELECTRONS DELIVERED FROM MEDICAL LINEAR ACCELERATOR

We focus on the comparative study of dosimetry protocols in radiotherapy for accelerated photon and electron delivered from medical linear accelerator (LINAC). In this study, a comparison between the protocols (TRS 398, DIN 6800-2 and TG 51) for both the electron and photon delivered from Clinac 2...

Mô tả đầy đủ

Chi tiết về thư mục
Tác giả chính: Meazea, A.K.M. Moinul Haque
Định dạng: Bài viết
Ngôn ngữ:Tiếng Anh
Được phát hành: EAST EUROPEAN JOURNAL OF PHYSICS 2025
Những chủ đề:
Truy cập trực tuyến:https://repository.auw.edu.bd/handle/123456789/914
_version_ 1857448965702680576
author Meazea, A.K.M. Moinul Haque
author_facet Meazea, A.K.M. Moinul Haque
author_sort Meazea, A.K.M. Moinul Haque
collection institutional Repository
description We focus on the comparative study of dosimetry protocols in radiotherapy for accelerated photon and electron delivered from medical linear accelerator (LINAC). In this study, a comparison between the protocols (TRS 398, DIN 6800-2 and TG 51) for both the electron and photon delivered from Clinac 2300CD and Clinac DHX 3186 were performed. We used photon beams with energies of 6 and 15 MV and electron beams of 4, 6, 9, 12, 15 and 18 MeV for both Medical Linac. In case of Clinac the maximum deviations for the relative dose at Dmax for the photon beam (15 MV) among the protocols was observed to be 1.18% between TRS-398 and TG-51, 1.56% between TG-51 and DIN 6800-2; and 0.41% between TRS-398 and DIN 6800-2. Conversely, these deviations were 3.67% between TRS-398 and TG-51, 3.92% between TG-51 and DIN 6800-2 for 4 MeV and 0.95% between TRS-398 and DIN 6800-2 in the case of Clinac 2300 CD for the PTW Markus and Exradin A10. For the measurement of the maximum absorbed dose depth to water using three protocols, the maximum deviations were observed between TRS 398 and TG-51 as well as TG51 and DIN 6800-2.
format Article
id 123456789-914
institution Asian University for Women
language English
publishDate 2025
publisher EAST EUROPEAN JOURNAL OF PHYSICS
record_format dspace
spelling 123456789-9142026-02-18T06:15:24Z STUDIES OF DOSIMETRY PROTOCOLS FOR ACCELERATED PHOTONS AND ELECTRONS DELIVERED FROM MEDICAL LINEAR ACCELERATOR Meazea, A.K.M. Moinul Haque TRS (Technical Report Series), TG (Task Group), DIN (Deutsches Institut für Normung). We focus on the comparative study of dosimetry protocols in radiotherapy for accelerated photon and electron delivered from medical linear accelerator (LINAC). In this study, a comparison between the protocols (TRS 398, DIN 6800-2 and TG 51) for both the electron and photon delivered from Clinac 2300CD and Clinac DHX 3186 were performed. We used photon beams with energies of 6 and 15 MV and electron beams of 4, 6, 9, 12, 15 and 18 MeV for both Medical Linac. In case of Clinac the maximum deviations for the relative dose at Dmax for the photon beam (15 MV) among the protocols was observed to be 1.18% between TRS-398 and TG-51, 1.56% between TG-51 and DIN 6800-2; and 0.41% between TRS-398 and DIN 6800-2. Conversely, these deviations were 3.67% between TRS-398 and TG-51, 3.92% between TG-51 and DIN 6800-2 for 4 MeV and 0.95% between TRS-398 and DIN 6800-2 in the case of Clinac 2300 CD for the PTW Markus and Exradin A10. For the measurement of the maximum absorbed dose depth to water using three protocols, the maximum deviations were observed between TRS 398 and TG-51 as well as TG51 and DIN 6800-2. 2025-08-04T10:22:38Z 2025-08-04T10:22:38Z 2020 Article https://repository.auw.edu.bd/handle/123456789/914 en application/pdf EAST EUROPEAN JOURNAL OF PHYSICS
spellingShingle TRS (Technical Report Series), TG (Task Group), DIN (Deutsches Institut für Normung).
Meazea, A.K.M. Moinul Haque
STUDIES OF DOSIMETRY PROTOCOLS FOR ACCELERATED PHOTONS AND ELECTRONS DELIVERED FROM MEDICAL LINEAR ACCELERATOR
title STUDIES OF DOSIMETRY PROTOCOLS FOR ACCELERATED PHOTONS AND ELECTRONS DELIVERED FROM MEDICAL LINEAR ACCELERATOR
title_full STUDIES OF DOSIMETRY PROTOCOLS FOR ACCELERATED PHOTONS AND ELECTRONS DELIVERED FROM MEDICAL LINEAR ACCELERATOR
title_fullStr STUDIES OF DOSIMETRY PROTOCOLS FOR ACCELERATED PHOTONS AND ELECTRONS DELIVERED FROM MEDICAL LINEAR ACCELERATOR
title_full_unstemmed STUDIES OF DOSIMETRY PROTOCOLS FOR ACCELERATED PHOTONS AND ELECTRONS DELIVERED FROM MEDICAL LINEAR ACCELERATOR
title_short STUDIES OF DOSIMETRY PROTOCOLS FOR ACCELERATED PHOTONS AND ELECTRONS DELIVERED FROM MEDICAL LINEAR ACCELERATOR
title_sort studies of dosimetry protocols for accelerated photons and electrons delivered from medical linear accelerator
topic TRS (Technical Report Series), TG (Task Group), DIN (Deutsches Institut für Normung).
url https://repository.auw.edu.bd/handle/123456789/914
work_keys_str_mv AT meazeaakmmoinulhaque studiesofdosimetryprotocolsforacceleratedphotonsandelectronsdeliveredfrommedicallinearaccelerator