A Study of Measurement of Relative Dose With Various Chamber for Small Field Dosimetry of 6 MV Photon Beam

The new technologies intensity modulated radio therapy (IMRT), image guided radio therapy (IGRT) and stereotactic radio therapy (SRT) are the improved radiotherapy techniques where proper commissioning of Clinac is necessary to save patient’s healthy cells from adverse effect of radiation. The IAE...

Description complète

Détails bibliographiques
Auteur principal: Meaze, AKM Moinul Haque
Format: Article
Langue:anglais
Publié: NUCLEAR SCIENCE AND APPLICATIONS 2025
Sujets:
Accès en ligne:https://repository.auw.edu.bd/handle/123456789/925
_version_ 1857448926174511104
author Meaze, AKM Moinul Haque
author_facet Meaze, AKM Moinul Haque
author_sort Meaze, AKM Moinul Haque
collection institutional Repository
description The new technologies intensity modulated radio therapy (IMRT), image guided radio therapy (IGRT) and stereotactic radio therapy (SRT) are the improved radiotherapy techniques where proper commissioning of Clinac is necessary to save patient’s healthy cells from adverse effect of radiation. The IAEA dosimetry protocol TRS-398 has been used to measure the absolute dose at 10 cm × 10 cm with CC13 (ionization) chamber. Later, the CC13 chamber was cross calibrated with CC01 (Ionization) and Razor (diode) chamber respectively for the measurement of dose in small fields. According Daisy Chaining Factor method, dose was measured for CC13 (ionization) to Razor (diode). On the other hand, the reference dose for small field was also measured for different field size(s) by applying newly proposed formalism (R. Alfonso et al. 2008) using CC13 (ionization) chamber and fitted with 4 th order polynomial fitting function where R 2=1. The variation of dose was observed as around 4% by CC01 (ionization) and Razor (diode) chambers for field sizes 1 cm × 1 cm field at reference condition in the cross-calibration technique. The sources uncertainties were calculated as per IAEA guidelines for both Type-A and Type- B. The combined standard uncertainty lies within 1.51% (1σ).
format Article
id 123456789-925
institution Asian University for Women
language English
publishDate 2025
publisher NUCLEAR SCIENCE AND APPLICATIONS
record_format dspace
spelling 123456789-9252026-02-18T06:15:14Z A Study of Measurement of Relative Dose With Various Chamber for Small Field Dosimetry of 6 MV Photon Beam Meaze, AKM Moinul Haque Intensity modulated radiotherapy, image guided radiotherapy, stereotactic radiotherapy, technical report series, source to surface distance The new technologies intensity modulated radio therapy (IMRT), image guided radio therapy (IGRT) and stereotactic radio therapy (SRT) are the improved radiotherapy techniques where proper commissioning of Clinac is necessary to save patient’s healthy cells from adverse effect of radiation. The IAEA dosimetry protocol TRS-398 has been used to measure the absolute dose at 10 cm × 10 cm with CC13 (ionization) chamber. Later, the CC13 chamber was cross calibrated with CC01 (Ionization) and Razor (diode) chamber respectively for the measurement of dose in small fields. According Daisy Chaining Factor method, dose was measured for CC13 (ionization) to Razor (diode). On the other hand, the reference dose for small field was also measured for different field size(s) by applying newly proposed formalism (R. Alfonso et al. 2008) using CC13 (ionization) chamber and fitted with 4 th order polynomial fitting function where R 2=1. The variation of dose was observed as around 4% by CC01 (ionization) and Razor (diode) chambers for field sizes 1 cm × 1 cm field at reference condition in the cross-calibration technique. The sources uncertainties were calculated as per IAEA guidelines for both Type-A and Type- B. The combined standard uncertainty lies within 1.51% (1σ). 2025-08-04T11:32:44Z 2025-08-04T11:32:44Z 2017 Article https://repository.auw.edu.bd/handle/123456789/925 en application/pdf NUCLEAR SCIENCE AND APPLICATIONS
spellingShingle Intensity modulated radiotherapy, image guided radiotherapy, stereotactic radiotherapy, technical report series, source to surface distance
Meaze, AKM Moinul Haque
A Study of Measurement of Relative Dose With Various Chamber for Small Field Dosimetry of 6 MV Photon Beam
title A Study of Measurement of Relative Dose With Various Chamber for Small Field Dosimetry of 6 MV Photon Beam
title_full A Study of Measurement of Relative Dose With Various Chamber for Small Field Dosimetry of 6 MV Photon Beam
title_fullStr A Study of Measurement of Relative Dose With Various Chamber for Small Field Dosimetry of 6 MV Photon Beam
title_full_unstemmed A Study of Measurement of Relative Dose With Various Chamber for Small Field Dosimetry of 6 MV Photon Beam
title_short A Study of Measurement of Relative Dose With Various Chamber for Small Field Dosimetry of 6 MV Photon Beam
title_sort study of measurement of relative dose with various chamber for small field dosimetry of 6 mv photon beam
topic Intensity modulated radiotherapy, image guided radiotherapy, stereotactic radiotherapy, technical report series, source to surface distance
url https://repository.auw.edu.bd/handle/123456789/925
work_keys_str_mv AT meazeakmmoinulhaque astudyofmeasurementofrelativedosewithvariouschamberforsmallfielddosimetryof6mvphotonbeam
AT meazeakmmoinulhaque studyofmeasurementofrelativedosewithvariouschamberforsmallfielddosimetryof6mvphotonbeam