Measurement of the neutron-induced fission cross-section of 241Am at the time-of-flight facility n TOF

The neutron-induced fission cross-section of 241Am has been measured relative to the standard fission cross-section of 235U between 0.5 and 20 MeV. The experiment was performed at the CERN n TOF facility. Fission fragments were detected by a fast ionization chamber by discriminating against the...

Fuld beskrivelse

Bibliografiske detaljer
Hovedforfatter: Meaze, AKM Moinul Haque
Format: Article
Sprog:engelsk
Udgivet: THE EUROPEAN PHYSICAL JOURNAL A 2025
Online adgang:https://repository.auw.edu.bd/handle/123456789/930
Beskrivelse
Summary:The neutron-induced fission cross-section of 241Am has been measured relative to the standard fission cross-section of 235U between 0.5 and 20 MeV. The experiment was performed at the CERN n TOF facility. Fission fragments were detected by a fast ionization chamber by discriminating against the α- particles from the high radioactivity of the samples. The high instantaneous neutron flux and the low background of the n TOF facility enabled us to obtain uncertainties of ≈ 5%. With the present results it was possible to resolve discrepancies between previous data sets and to confirm current evaluations, thus providing important information for design studies of future reactors with improved fuel burn-up.