Measurement of the neutron-induced fission cross-section of 241Am at the time-of-flight facility n TOF

The neutron-induced fission cross-section of 241Am has been measured relative to the standard fission cross-section of 235U between 0.5 and 20 MeV. The experiment was performed at the CERN n TOF facility. Fission fragments were detected by a fast ionization chamber by discriminating against the...

Szczegółowa specyfikacja

Opis bibliograficzny
1. autor: Meaze, AKM Moinul Haque
Format: Artykuł
Język:angielski
Wydane: THE EUROPEAN PHYSICAL JOURNAL A 2025
Dostęp online:https://repository.auw.edu.bd/handle/123456789/930
Opis
Streszczenie:The neutron-induced fission cross-section of 241Am has been measured relative to the standard fission cross-section of 235U between 0.5 and 20 MeV. The experiment was performed at the CERN n TOF facility. Fission fragments were detected by a fast ionization chamber by discriminating against the α- particles from the high radioactivity of the samples. The high instantaneous neutron flux and the low background of the n TOF facility enabled us to obtain uncertainties of ≈ 5%. With the present results it was possible to resolve discrepancies between previous data sets and to confirm current evaluations, thus providing important information for design studies of future reactors with improved fuel burn-up.